  [物理學]

  The use of heat pumps has been held back largely by skepticism about advertisers claims that heat pumps can provide as many as two units of thermal energy for each unit of electrical energy used, thus apparently contradicting the principle of energy conservation.

  Heat pumps circulate a fluid refrigerant that cycles alternatively from its liquid phase to its vapor phase in a closed loop. The refrigerant, starting as a low-temperature, low-pressure vapor, enters a compressor driven by an electric motor. The refrigerant leaves the compressor as a hot, dense vapor and flows through a heat exchanger called the condenser, which transfers heat from the refrigerant to a body of air. Now the refrigerant, as a high-pressure, cooled liquid, confronts a flow restriction which causes the pressure to drop. As the pressure falls, the refrigerant expands and partially vaporizes, becoming chilled. It then passes through a second heat exchanger, the evaporator, which transfers heat from the air to the refrigerant, reducing the temperature of this second body of air. Of the two heat exchangers, one is located inside, and the other one outside the house, so each is in contact with a different body of air: room air and outside air, respectively.

  The flow direction of refrigerant through a heat pump is controlled by valves. When the refrigerant flow is reversed, the heat exchangers switch function. This flow-reversal capability allows heat pumps either to heat or cool room air.

  Now, if under certain conditions a heat pump puts out more thermal energy than it consumes in electrical energy, has the law of energy conservation been challenged? No, not even remotely: the additional input of thermal energy into the circulating refrigerant via the evaporator accounts for the difference in the energy equation.

  Unfortunately there is one real problem. The heating capacity of a heat pump decreases as the outdoor temperature falls. The drop in capacity is caused by the lessening amount of refrigerant mass moved through the compressor at one time. The heating capacity is proportional to this mass flow rate: the less the mass of refrigerant being compressed, the less the thermal load it can transfer through the heat-pump cycle. The volume flow rate of refrigerant vapor through the single-speed rotary compressor used in heat pumps is approximately constant. But cold refrigerant vapor entering a compressor is at lower pressure than warmer vapor. Therefore, the mass of cold refrigerant and thus the thermal energy it carries is less than if the refrigerant vapor were warmer before compression.

  Here, then, lies a genuine drawback of heat pumps: in extremely cold climates where the most heat is needed heat pumps are least able to supply enough heat.

  1. The primary purpose of the text is to

  [A] explain the differences in the working of a heat pump when the outdoor temperature changes.

  [B] contrast the heating and the cooling modes of heat pumps.

  [C] describe heat pumps, their use, and factors affecting their use.

  [D] advocate the more widespread use of heat pumps.

  2. The author resolves the question of whether heat pumps run counter to the principle of energy conservation by

  [A] carefully qualifying the meaning of that principle.

  [B] pointing out a factual effort in the statement that gives rise to this question.

  [C] supplying additional relevant facts.

  [D] denying the relevance of that principle to heat pumps.

  3. It can be inferred from the text that, in the course of a heating season, the heating capacity of a heat pump is greatest when

  [A] heating is least essential.

  [B] electricity rates are lowest.

  [C] its compressor runs the fastest.

  [D] outdoor temperatures hold steady.

  4. If the authors assessment of the use of heat pumps is correct, which of the following best expresses the lesson that advertisers should learn from this case?

  [A] Do not make exaggerated claims about the products you are trying to promote.

  [B] Focus your advertising campaign on vague analogies and veiled implications instead of on facts.

  [C] Do not use facts in your advertising that will strain the prospective clients ability to believe.

  [D] Do not assume in your advertising that the prospective clients know even the most elementary scientific principles.

  5. The text suggests that heat pumps would be used more widely if

  [A] they could also be used as air conditioners.

  [B] they could be moved around to supply heat where it is most needed.

  [C] their heat output could be thermostatically controlled.

  [D] people appreciated the role of the evaporator in the energy equation.

  

  SAMPLE 10

  [物理學]

  The use of heat pumps has been held back largely by skepticism about advertisers claims that heat pumps can provide as many as two units of thermal energy for each unit of electrical energy used, thus apparently contradicting the principle of energy conservation.

  Heat pumps circulate a fluid refrigerant that cycles alternatively from its liquid phase to its vapor phase in a closed loop. The refrigerant, starting as a low-temperature, low-pressure vapor, enters a compressor driven by an electric motor. The refrigerant leaves the compressor as a hot, dense vapor and flows through a heat exchanger called the condenser, which transfers heat from the refrigerant to a body of air. Now the refrigerant, as a high-pressure, cooled liquid, confronts a flow restriction which causes the pressure to drop. As the pressure falls, the refrigerant expands and partially vaporizes, becoming chilled. It then passes through a second heat exchanger, the evaporator, which transfers heat from the air to the refrigerant, reducing the temperature of this second body of air. Of the two heat exchangers, one is located inside, and the other one outside the house, so each is in contact with a different body of air: room air and outside air, respectively.

  The flow direction of refrigerant through a heat pump is controlled by valves. When the refrigerant flow is reversed, the heat exchangers switch function. This flow-reversal capability allows heat pumps either to heat or cool room air.

  Now, if under certain conditions a heat pump puts out more thermal energy than it consumes in electrical energy, has the law of energy conservation been challenged? No, not even remotely: the additional input of thermal energy into the circulating refrigerant via the evaporator accounts for the difference in the energy equation.

  Unfortunately there is one real problem. The heating capacity of a heat pump decreases as the outdoor temperature falls. The drop in capacity is caused by the lessening amount of refrigerant mass moved through the compressor at one time. The heating capacity is proportional to this mass flow rate: the less the mass of refrigerant being compressed, the less the thermal load it can transfer through the heat-pump cycle. The volume flow rate of refrigerant vapor through the single-speed rotary compressor used in heat pumps is approximately constant. But cold refrigerant vapor entering a compressor is at lower pressure than warmer vapor. Therefore, the mass of cold refrigerant and thus the thermal energy it carries is less than if the refrigerant vapor were warmer before compression.

  Here, then, lies a genuine drawback of heat pumps: in extremely cold climates where the most heat is needed heat pumps are least able to supply enough heat.

  1. The primary purpose of the text is to

  [A] explain the differences in the working of a heat pump when the outdoor temperature changes.

  [B] contrast the heating and the cooling modes of heat pumps.

  [C] describe heat pumps, their use, and factors affecting their use.

  [D] advocate the more widespread use of heat pumps.

  2. The author resolves the question of whether heat pumps run counter to the principle of energy conservation by

  [A] carefully qualifying the meaning of that principle.

  [B] pointing out a factual effort in the statement that gives rise to this question.

  [C] supplying additional relevant facts.

  [D] denying the relevance of that principle to heat pumps.

  3. It can be inferred from the text that, in the course of a heating season, the heating capacity of a heat pump is greatest when

  [A] heating is least essential.

  [B] electricity rates are lowest.

  [C] its compressor runs the fastest.

  [D] outdoor temperatures hold steady.

  4. If the authors assessment of the use of heat pumps is correct, which of the following best expresses the lesson that advertisers should learn from this case?

  [A] Do not make exaggerated claims about the products you are trying to promote.

  [B] Focus your advertising campaign on vague analogies and veiled implications instead of on facts.

  [C] Do not use facts in your advertising that will strain the prospective clients ability to believe.

  [D] Do not assume in your advertising that the prospective clients know even the most elementary scientific principles.

  5. The text suggests that heat pumps would be used more widely if

  [A] they could also be used as air conditioners.

  [B] they could be moved around to supply heat where it is most needed.

  [C] their heat output could be thermostatically controlled.

  [D] people appreciated the role of the evaporator in the energy equation.

  

主站蜘蛛池模板: 国产午夜无码片在线观看| 美女扒开粉嫩尿口的漫画| 色吊丝中文字幕| 永久免费无码日韩视频| 皇上往下边塞玉器见客| 精品女同一区二区| 欧美日韩亚洲国产| 日日操夜夜操视频| 在线视频你懂的国产福利| 国产成人综合久久精品免费| 午夜天堂精品久久久久| 亚洲欧美日韩三级| 久久狠狠色噜噜狠狠狠狠97| jealousvue熟睡入侵中| 99r精品在线| 孩交videos精品乱子豆奶视频| 综合欧美一区二区三区| 欧美一级大片在线观看| 好吊色青青青国产在线观看| 国产欧美另类精品久久久| 免费a级毛视频| 久久精品人人做人人爽电影蜜月| 99久久人人爽亚洲精品美女| 老司机精品免费视频| 欧美毛多水多肥妇| 无翼少无翼恶女漫画全彩app| 奇米综合四色77777久久| 国产欧美一区二区三区免费| 午夜私人影院免费体验区| 亚洲国产成人精品无码区在线网站| 亚洲av综合色区无码专区桃色| 久久青青草原国产精品免费| jux900被公每天侵犯的我| 麻豆亚洲av熟女国产一区二| 波多野结衣中文字幕一区二区三区 | 午夜爱爱免费视频| 亚1州区2区三区4区产品| sihu免费观看在线高清| 色综合综合色综合色综合| 西西人体www44rt大胆高清| 欧美人与zoxxxx视频|